18 Scope Hospital Air Drying Cabinet

MASS™ truAIR™ HEPA-Grade Endoscope Drying Cabinet
SAS-18P-HA

MASS™ truAIR™ Drying Cabinet
Storage and Protection for 18 flexible endoscopes.
18 3⁄4”D X 40 7⁄8”W X 93 3⁄4”H

Provides HEPA-filtered, airflow directly into the cabinet itself and continuous positive air pressure through each endoscope lumen at 99.97% filtration up to 0.3µm.

Fully compliant with The Joint Commission, AORN, SGNA, and other standards and guidelines.1-5

This MASS™ proprietary system achieves these standards at an unprecedented value, enabling most facilities to meet higher standards and provide their patients with the best in infection control for endoscope storage.

Get a Quote Contact Us
Call Consultant

Standard Features

Air Supply

  • Hospital Air

Materials

  • Powder coated metal
    – Rust-proof
    – Antimicrobial paint

Scope Hooks

  • Store 18 flexible endoscopes

Reusable Drying Connectors

  • Including Auxiliary Water

Padded Lower Wall

  • Distal tip protection

Door

  • Locking glass door

Ventilation

  • MASS™ truHEPA™ filtered air

Air Manifold

  • Quick disconnect
  • 18 connectors

Removable Drip Tray

Center Separator Scope Rack

  • Minimize risk of overlapping umbilical and insertion tube

Pre-Cut Mounting Slots

  • Simplifies the installation process

Notched Cabinet Base

  •  Flush fit for coved flooring

Downloads

Citations
1. Burlingame, B., Denholm, B., Link, T., Ogg, M., Spruce, L., Spry, C., Van Wicklin, S., Wood, A. Guidelines for Perioperative Practice. Denver, CO: Association of periOperative Registered Nurses; 2016.
2. A Joint Commission/FDA Webinar on Reprocessing of Scopes Transcript. The Joint Commission. Available at: http://www.jointcommission.org/assets/1/6/A_Joint_CommissionFDA_Webinar_on_Reprocessing_of_Scopes_Transcript.pdf. Accessed April 26, 2016.
3. GI Endoscope Reprocessing. Olympus America. 2016. Available at: http://medical.olympusamerica.com/customer-resources/cleaning-disinfection-sterilization/cds-instructions/gi-endoscope-reprocessing. Accessed May 19, 2016.
4. Instructions for Use (Reprocessing/Maintenance). Pentax. Available at: http://pentaxmedical.com/pentax/download/fstore/uploadFiles/Pdfs/Other%20Documents/Z863-R16_E_90i,%2090K(reprocessing).pdf. Accessed May 19, 2016.
5. Society of Gastroenterology Nurses and Associates, Inc. Standards of Infection Prevention in Reprocessing of Flexible Gastrointestinal Endoscopes, 2015. Available at: https://www.sgna.org/Portals/0/Standards%20for%20reprocessing%20 endoscopes_FINAL_2.22.pdf. Accessed May 12, 2016